Nan fen chak ane, pwoblèm sekirite yo vin tounen yon fenèt enpòtan pou fè tès plant elektrik fotovoltaik. Avèk gwo nèj ak sezon fredi, tanperati ki ba ak gwo frèt, klima sèk, ak iradyasyon febli, nan moman sa a, li nesesè yo peye plis atansyon sou plant elektrik fotovoltaik epi fè yo travay estab nan lòd yo pote benefis dirab.
Ki lyen ki an danje? Ki faktè ki mennen nan pèt jenerasyon pouvwa? Ki jan pou fè pou evite li? Ann regle li jodi a.
Kab ak pwoteksyon dife yo enpòtan
Nan nenpòt pwojè jeni, prevansyon dife se premye priyorite. Pouvwa a nan estasyon elektrik fotovoltaik pote pa câbles AC. Anjeneral pale, danje dife nan estasyon elektrik nan kay la piti. Kapasite estasyon elektrik sa yo jeneralman ant 20kW ak 40kW. Malgre ke vòltaj ki konekte nan kadriyaj la ka varye, aktyèl la an jeneral pa gwo. Pou egzanp, aktyèl pwodiksyon maksimòm 40kW se sou 66A. Pwobabilite pou dife ki te koze pa estasyon elektrik la li menm se piti anpil. Pou yon gwo estasyon pouvwa fotovoltaik, aktyèl pwodiksyon sistèm lan relativman gwo. Pou egzanp, aktyèl pwodiksyon total nan yon etalaj 2.5MW sub redwi se plis pase 3000 A, ak varyateur la itilize se relativman gwo. Gen sub redwi kabinè konbinezon, ak câbles yo rekòmande pou itilize flanm dife redwi ignifuge kòb kwiv mete diminye câbles nwayo. Pandan operasyon an nan estasyon elektrik la, câbles yo ta dwe tcheke chak sis mwa asire bon kontinwite ak sekirite. Nan sezon fredi, tanperati deyò a ba, rive nan mwens dizèn degre nan kèk zòn. Malgre ke kab la ka izole pandan tap mete, kouch ekstèn kab la ka domaje apre tanperati repete monte ak tonbe. Si yo jwenn li, li ta dwe ranplase nan tan.
Tcheke tèminal bò DC yo ak câbles PV plis
The 4mm² or 6mm² PV photovoltaic special cable used on the DC side, the 4mm² specification is more widely used and fully meets the input requirements of the module current. However, from the feedback of many actual cases, it is more common for the DC terminal to be burned, which is generally caused by the lack of tight pressure lines during installation. If the DC side terminal is found to be damaged during the daily inspection, the terminal of the same specification should be replaced in time, and the metal core of the terminal must be pressed tightly. The pressing length should be Greater than or equal to 40mm, and pay attention to the positive and negative polarity when connecting.
Tcheke pou bon baz
According to the requirements of relevant photovoltaic power station technical specifications, the grounding resistance value of lightning protection grounding is generally between 410Ω; the grounding resistance of working grounding is generally less than 1Ω. When the total capacity of low reduce voltage power equipment does not exceed 100kVA, the grounding resistance is not allowed to exceed 10Ω. The main purpose is to quickly lead the surge current to the ground when lightning occurs, and protect equipment and personnel from lightning strikes to the greatest extent possible. The ground wire is generally made of metal hot reduce dip galvanized steel, which should be done during the construction stage of the power station. The common grounding line is flat steel sheet/strip, the general specification is 40mm (width) 4mm (thickness), and its length should be more than 2.5m, buried in the ground, the depth should be more than 1m from the ground, in order to play a good guide. Nano effect. Failure to do a good job in grounding not only poses a safety hazard, but also often causes grounding fault codes, causing the system to stop working.
Netwayaj konpozan
Modil yo toujou sous revni pou plant elektrik fotovoltaik. Gen anpil enpurte nan atmosfè a. Lè rankontre lapli ak nèj, anpil nan yo pral bourade sou tè a oswa sifas objè yo. Modil yo ekspoze nan lè a. Lapli ak nèj yo souvan nan sezon fredi. Anpil redwi. Si konpozan yo netwaye souvan, pwodiksyon an ka maksimize nan entansite limite a menm si iradyasyon an redwi.
Lè w retire nèj oswa pousyè nan eleman, kenbe pwen sa yo nan tèt ou:
1) pa etap sou eleman yo dirèkteman. redwi redwi redwi Zouti espesyal pou netwaye divès konpozan ki disponib.
2) Rense eleman yo ak dlo cho. redwi diminye diminye Ou ka sèvi ak dlo nan tanperati chanm epi chwazi yon zam dlo ki gen yon pi gwo enpak.
3) Pa sèvi ak zouti metal di tankou pèl oswa pèl pou pèl nèj oswa glas. redwi redwi redwi zouti kawotchou ka itilize pou pwoteje sifas eleman yo.
4) Si gen nèj sou sifas modil la, li ta dwe netwaye nan tan. Pa rete tann pou yon tan long netwaye nèj la. Nèj la fonn ak jele ankò, sa ki ogmante difikilte pou netwaye ak ogmante pwobabilite pou domaj modil la.
5) Si nèj la sou modil la trè epè, premye sèvi ak yon bale mou pou retire nèj la, ak Lè sa a, sèvi ak yon mop twal konplètman netwaye sifas la vè.
Nan sezon fredi, plant elektrik fotovoltaik yo ta dwe konsantre sou epi fè aspè ki anwo yo, epi rezoud pwen ki anwo yo, pou plant elektrik fotovoltaik ou yo ka siviv sezon fredi a piti piti epi fè pwofi fiks.